pellimits.com
CAS 1314-13-2Metal Fume

Zinc Oxide (Fume)

OSHA PEL 5 mg/m³· Metal Fumes · NIOSH method NIOSH 7030

OSHA PEL (8-hr TWA)
5 mg/m³
Target organs
Metal fume fever; respiratory tract
Sampling method
NIOSH 7030

Zinc Oxide (Fume) (1314-13-2)

Zinc Oxide (Fume) is a metal fume with CAS Registry Number 1314-13-2. Under the OSHA air contaminants standard (29 CFR 1910.1000), its Permissible Exposure Limit (PEL) — the legal 8-hour time-weighted average (TWA) for general industry — is 5 mg/m3. The principal target organs are the Metal fume fever; respiratory tract, and workplace air is sampled and analyzed by NIOSH 7030.

Exposure Limits at a Glance

Limit Value Basis
OSHA PEL (8-hr TWA) 5 mg/m3 29 CFR 1910.1000
NIOSH REL See note below NIOSH Pocket Guide
Hazard Class Metal Fume Metal Fume
Target Organs Metal fume fever; respiratory tract NIOSH / OSHA
Sampling Method NIOSH 7030 NIOSH Manual of Analytical Methods

NIOSH REL note: NIOSH RELs target the respirable fraction and apply to the specific metal species. The REL is a non-regulatory recommendation; where a NIOSH REL exists it is typically more protective than the OSHA PEL.

How It Enters the Body & Health Effects

Exposure to Zinc Oxide (Fume) is assessed against the Metal fume fever; respiratory tract — the organ systems most consistently affected in occupational studies. Employers must ensure no employee’s 8-hour TWA exceeds the 5 mg/m3 PEL, and must use engineering controls, work practices, and — where required — respiratory protection to keep exposures at or below that level.

Sampling & Compliance Notes

  1. Determine whether the exposure is a full-period 8-hour TWA or a short-term / ceiling scenario. Ceiling and STEL excursions apply to several Metal Fume-class agents regardless of the 8-hour average.
  2. Calibrate personal sampling pumps before and after each shift and record flow rates; method NIOSH 7030 specifies media, flow, and analysis.
  3. Compare analytical results to the OSHA PEL of 5 mg/m3 and the NIOSH REL. Document the higher of the two for internal exposure-control targets.
  4. Where the PEL includes a “skin” notation, dermal absorption can contribute to the dose — glove selection and hygiene facilities are part of compliance.

Frequently Asked Questions

What is the OSHA PEL for Zinc Oxide (Fume)?

The OSHA Permissible Exposure Limit (8-hour TWA) for Zinc Oxide (Fume) is 5 mg/m3.

What is the CAS number for Zinc Oxide (Fume)?

The CAS Registry Number for Zinc Oxide (Fume) is 1314-13-2.

What are the target organs for Zinc Oxide (Fume)?

The primary target organs are the Metal fume fever; respiratory tract.

How do you measure Zinc Oxide (Fume) in workplace air?

Use NIOSH analytical method NIOSH 7030 for air sampling and laboratory analysis.

What hazard class is Zinc Oxide (Fume)?

It is classified here as a Metal Fume (Metal Fume).

Related Metal Fume chemicals