pellimits.com
CAS 7440-36-0Metal Fume

Antimony

OSHA PEL 0.50 mg/m³· Metal Fumes · NIOSH method NIOSH 7300

OSHA PEL (8-hr TWA)
0.50 mg/m³
Target organs
Respiratory tract; skin; heart
Sampling method
NIOSH 7300

Antimony (7440-36-0)

Antimony is a metal fume with CAS Registry Number 7440-36-0. Under the OSHA air contaminants standard (29 CFR 1910.1000), its Permissible Exposure Limit (PEL) — the legal 8-hour time-weighted average (TWA) for general industry — is 0.5 mg/m3. The principal target organs are the Respiratory tract; skin; heart, and workplace air is sampled and analyzed by NIOSH 7300.

Exposure Limits at a Glance

Limit Value Basis
OSHA PEL (8-hr TWA) 0.5 mg/m3 29 CFR 1910.1000
NIOSH REL See note below NIOSH Pocket Guide
Hazard Class Metal Fume Metal Fume
Target Organs Respiratory tract; skin; heart NIOSH / OSHA
Sampling Method NIOSH 7300 NIOSH Manual of Analytical Methods

NIOSH REL note: NIOSH RELs target the respirable fraction and apply to the specific metal species. The REL is a non-regulatory recommendation; where a NIOSH REL exists it is typically more protective than the OSHA PEL.

How It Enters the Body & Health Effects

Exposure to Antimony is assessed against the Respiratory tract; skin; heart — the organ systems most consistently affected in occupational studies. Employers must ensure no employee’s 8-hour TWA exceeds the 0.5 mg/m3 PEL, and must use engineering controls, work practices, and — where required — respiratory protection to keep exposures at or below that level.

Sampling & Compliance Notes

  1. Determine whether the exposure is a full-period 8-hour TWA or a short-term / ceiling scenario. Ceiling and STEL excursions apply to several Metal Fume-class agents regardless of the 8-hour average.
  2. Calibrate personal sampling pumps before and after each shift and record flow rates; method NIOSH 7300 specifies media, flow, and analysis.
  3. Compare analytical results to the OSHA PEL of 0.5 mg/m3 and the NIOSH REL. Document the higher of the two for internal exposure-control targets.
  4. Where the PEL includes a “skin” notation, dermal absorption can contribute to the dose — glove selection and hygiene facilities are part of compliance.

Frequently Asked Questions

What is the OSHA PEL for Antimony?

The OSHA Permissible Exposure Limit (8-hour TWA) for Antimony is 0.5 mg/m3.

What is the CAS number for Antimony?

The CAS Registry Number for Antimony is 7440-36-0.

What are the target organs for Antimony?

The primary target organs are the Respiratory tract; skin; heart.

How do you measure Antimony in workplace air?

Use NIOSH analytical method NIOSH 7300 for air sampling and laboratory analysis.

What hazard class is Antimony?

It is classified here as a Metal Fume (Metal Fume).

Related Metal Fume chemicals

Other metal fumes with lower or comparable exposure limits.